Publication: Determination of Nickel, Copper and Zinc in Water Samples After Cloud Point Extraction Using Ammonium O,o-Dicyclohexyldithiophosphate and Triton X-114 by Flame Atomic Absorption Spectrometry
| dc.authorscopusid | 12645940600 | |
| dc.authorscopusid | 20733997400 | |
| dc.authorscopusid | 6602726308 | |
| dc.contributor.author | Yaĝan, M.Y. | |
| dc.contributor.author | Efendioǧlu, A. | |
| dc.contributor.author | Bati, B. | |
| dc.date.accessioned | 2020-06-21T14:27:43Z | |
| dc.date.available | 2020-06-21T14:27:43Z | |
| dc.date.issued | 2012 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Yaĝan] Mehtap, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Efendioǧlu] Ayşegül, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bati] Bekir, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A simple and practical cloud point extraction-preconcentration method for trace amounts of Ni, Cu and Zn by flame atomic absorption spectrophotometry was proposed. The laboratory made-reagent ammonium O,O-dicyclohexyldithiophosphate which has not previously been used for analytical purpose and the nonionic surfactant Triton X-114 were used for cloud point extraction. The cloud point was formed in the presence of NaCl at 60°C. After phase separation, the surfactant-rich phase was diluted with ethanol acidified with 0.1 mol L -1 HNO<inf>3</inf> and the final solution was determined by flame atomic absorption spectrometry. Under the optimal experimental conditions, calibration graphs were linear in the range of 20-120, 10-80 and 6-60 μg L-1, with detection limits of 1.41, 1.51 and 2.92 μg L -1 for Ni, Cu and Zn, respectively. The proposed method was applied to the determination of Ni, Cu and Zn in natural water samples and certified reference alloys. Results found were in good agreement with certified values. | en_US |
| dc.identifier.endpage | 2502 | en_US |
| dc.identifier.issn | 0970-7077 | |
| dc.identifier.issue | 6 | en_US |
| dc.identifier.scopus | 2-s2.0-84861711447 | |
| dc.identifier.scopusquality | Q4 | |
| dc.identifier.startpage | 2497 | en_US |
| dc.identifier.volume | 24 | en_US |
| dc.identifier.wos | WOS:000305033900026 | |
| dc.language.iso | en | en_US |
| dc.publisher | Chemical Publishing Co. | en_US |
| dc.relation.ispartof | Asian Journal of Chemistry | en_US |
| dc.relation.journal | Asian Journal of Chemistry | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Ammonium O | en_US |
| dc.subject | Atomic Absorption Spectrometry | en_US |
| dc.subject | Cloud Point Extraction | en_US |
| dc.subject | O-Dicyclohexyldithiophosphate | en_US |
| dc.subject | Triton X-114 | en_US |
| dc.title | Determination of Nickel, Copper and Zinc in Water Samples After Cloud Point Extraction Using Ammonium O,o-Dicyclohexyldithiophosphate and Triton X-114 by Flame Atomic Absorption Spectrometry | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |