Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.

Publication:
Batch and Column Studies on Zinc Removal From Industrial Wastewater Using Natural Clinoptilolite: Factors Affecting Sorption Capacities and Kinetics

dc.authorscopusid6603645309
dc.contributor.authorBeyazit, N.
dc.date.accessioned2020-06-21T14:16:50Z
dc.date.available2020-06-21T14:16:50Z
dc.date.issued2013
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Beyazit] Nevzat, Department of Environmental Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe ability of natural zeolite (clinoptilolite) to take up zinc (Zn) ions from industrial wastewater was studied in batch reactors and fixed bed columns. The sorption capacities and kinetic behavior of clinoptilolite for Zn ions was studied as a function of adsorbent dosage, particle size, pH, temperature, and conditioning conditions. Fixed bed experiments were conducted in order to examine Zn uptake by clinoptilolite (0.5–0.85 mm) using three different volumetric flow rates of 2–4–6BVh-1 under a initial concentration of 18.4mg L-1 and initial pH value equal to 4 and ambient temperature (23ºC). The sorption capacities and removal efficients was strongly dependent on pH, and to a lesser extent on other parameters examined. The highest sorption capacities were obtained at pH 4, leading to 0.34 and 2.38mg g-1 of clinoptilolite for the batch and column studies, respectively. The XRD pattern of the as-received, and treated clinoptilolite (with both 10% HNO<inf>3</inf> and 0.73M NaCl at pH10) showed significant change in the position of the most intense peaks, leading to some destructions on the crystal structure of clinoptilolite. The analysis of sorption kinetics were examined using pseudo-second-order and intra-particle diffusion models. The sorption of Zn on clinoptilolite at different ranges of experimental parameters followed only pseudo-second-order kinetic model with high correlation coefficient, suggesting that the sorption mechanism might be a chemisorption process. The highest rate coefficient (k<inf>2</inf>) was obtained at pH 2, which was 7.2 g mg-1min-1. The intra-particle diffusion was not rate limiting step since the low correlation coeefficients were obtained and deviation from the origin was observed. In column studies, the decrease of the flow rate resulted in increase in both breakthrough and ion exchange capacities, optimal results were obtained at flow rates lower than 6 bed volume (BV h-1). The column, which was saturated at flow rate of 3mL min-1, was regererated with 0.73M NaCl at 0.5mL min-1. Desorption efficiency was 83%. Clinoptilolite samples from Turkey are effective for removing heavy metals from industrial wastewater. © 2013 Taylor & Francis.en_US
dc.identifier.doi10.1080/02772248.2012.749589
dc.identifier.endpage68en_US
dc.identifier.issn0277-2248
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-84870761685
dc.identifier.scopusqualityQ3
dc.identifier.startpage45en_US
dc.identifier.urihttps://doi.org/10.1080/02772248.2012.749589
dc.identifier.volume95en_US
dc.identifier.wosWOS:000315156400005
dc.identifier.wosqualityQ4
dc.institutionauthorBeyazit, N.
dc.language.isoenen_US
dc.publisherTaylor and Francis Ltd. michael.wagreich@univie.ac.aten_US
dc.relation.ispartofToxicological and Environmental Chemistryen_US
dc.relation.journalToxicological and Environmental Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectClinoptiloliteen_US
dc.subjectIndustrial Wastewateren_US
dc.subjectSorption Kineticen_US
dc.subjectZn Removalen_US
dc.titleBatch and Column Studies on Zinc Removal From Industrial Wastewater Using Natural Clinoptilolite: Factors Affecting Sorption Capacities and Kineticsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files