Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.

Publication:
Determination of Cd(II) by FAAS in Turkish Cigarette Tobacco: A Pre-Concentration Procedure with Diethyldithiocarbamate Immobilized Amberlite XAD-2 Resin

dc.authorscopusid6602321147
dc.authorscopusid49664046100
dc.authorscopusid57217274048
dc.contributor.authorFatma Aygün, S.F.
dc.contributor.authorUstaosman, B.C.
dc.contributor.authorKaracan, M.
dc.date.accessioned2025-12-10T22:16:08Z
dc.date.issued2012
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Fatma Aygün] Seker, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Ustaosman] Basak Caner, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Karacan] Meral, Department of Physics, Arts and Sciences Faculty, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA simple and rapid procedure for the pre-concentration of Cd(II) in Turkish cigarette tobacco was developed. Present Cd(II) in the tobacco samples was pre-concentrated by sodium diethyldithiocarbamate immobilized Amberlite XAD-2 resin and determinations were carried out by using flame atomic absorption spectrometry. Parameters such as the effects of pH, nitric acid concentration and flow rate on the pre-concentration procedure were investigated. A pre-concentration factor of 100 was achived by employing optimum conditions. The calibration plot for Cd(II) was linear in 0.1-2.0 mg mL-1 concentration range with the detection limit of 0.03 mg mL-1 and the relative standard deviation (RSD) was 2.3 % for the overall procedure (n = 6). The accuracy of the proposed procedure was evaluated by means of cadmium determination in certified reference oriental tobacco leaves (CTA-OTL-1). The result obtained was in good agreement (1.07 ± 0.14 mg kg-1) with certified value (1.12 ± 0.12 mg kg-1). The procedure was applied to the determination of Cd(II) in cigarette tobacco samples. The concentration of Cd(II) in the two cigarettes tobacco samples was determined as 2.5 and 2.8 mg kg-1, respectively.en_US
dc.identifier.endpage1553en_US
dc.identifier.issn0970-7077
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84861669689
dc.identifier.scopusqualityQ4
dc.identifier.startpage1551en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/35077
dc.identifier.volume24en_US
dc.identifier.wosqualityN/A
dc.language.isoenen_US
dc.publisherChemical Publishing Co.en_US
dc.relation.ispartofAsian Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAmberlite Xad-2en_US
dc.subjectCadmiumen_US
dc.subjectFlame Atomic Absorption Spectrometryen_US
dc.subjectTobacco Cigaretteen_US
dc.titleDetermination of Cd(II) by FAAS in Turkish Cigarette Tobacco: A Pre-Concentration Procedure with Diethyldithiocarbamate Immobilized Amberlite XAD-2 Resinen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files