Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.

Publication:
Square Wave Voltammetric Determination of Valproic Acid in Pharmaceutical Preparations

dc.authorscopusid55767084600
dc.authorscopusid6603492027
dc.contributor.authorTürköz Acar, E.T.
dc.contributor.authorNur Onar, A.N.
dc.date.accessioned2020-06-21T13:40:34Z
dc.date.available2020-06-21T13:40:34Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Türköz Acar] Ebru, Department of Analytical Chemistry, Yeditepe University, Istanbul, Turkey, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Nur Onar] Atiye, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThe electrochemical behavior of valproic acid (VAL) was investigated using square wave voltammetry, cyclic voltammetry, and sampled direct current polarography and a new square wave voltammetric method was developed for determination of VAL in pharmaceutical preparations. VAL showed two reduction peaks at about -0.2 V and -0.8 V vs. Ag/AgCl 3 M KCl with a hanging mercury drop electrode in 0.05 M pH 3.3 Britton-Robinson (BR) buffer. These peaks were named peak I and peak II, respectively. The types of limiting current of both peaks were determined as diffusion controlled based on cyclic voltammetry studies. A linear calibration graph was obtained in the range 1.46 × 10-4 -1.0 × 10-3 M. The limit of detection (LOD) and limit of quantification (LOQ) were 1.09 × 10-4 M (21.05 μg/mL) and 1.10 × 10-4 M (144.20 μg/mL), respectively. Recovery studies for the accuracy of the method were performed by adding known amounts of VAL and it was found to be 109.67 ± 4.85%. The proposed method was successfully applied to pharmaceutical products on the market. © 2016 TÜB̄TAK.en_US
dc.identifier.doi10.3906/kim-1504-81
dc.identifier.endpage116en_US
dc.identifier.issn1300-0527
dc.identifier.issn1303-6130
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-84958952352
dc.identifier.scopusqualityQ3
dc.identifier.startpage106en_US
dc.identifier.urihttps://doi.org/10.3906/kim-1504-81
dc.identifier.volume40en_US
dc.identifier.wosWOS:000368558900001
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherTÜBİTAK erdin@metu.edu.tren_US
dc.relation.ispartofTurkish Journal of Chemistryen_US
dc.relation.journalTurkish Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCarboxylic Acid Electrochemical Reductionen_US
dc.subjectDrug Determinationen_US
dc.subjectSquare Wave Voltammetryen_US
dc.subjectValproate Analysisen_US
dc.subjectValproic Aciden_US
dc.titleSquare Wave Voltammetric Determination of Valproic Acid in Pharmaceutical Preparationsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files