Bilgilendirme: Kurulum ve veri kapsamındaki çalışmalar devam etmektedir. Göstereceğiniz anlayış için teşekkür ederiz.

Publication:
Effect of Interrupted Motion on the Cyclic Fatigue Resistance of Reciprocating Nickel-Titanium Instruments

dc.authorscopusid56471565700
dc.authorscopusid22934205900
dc.authorscopusid57194336212
dc.authorwosidKeskin, Cangul/Aca-8702-2022
dc.authorwosidInan, Umran/V-3634-2019
dc.contributor.authorKeskin, C.
dc.contributor.authorInan, U.
dc.contributor.authorDemiral, M.
dc.contributor.authorIDKeskin, Cangül/0000-0001-8990-4847
dc.date.accessioned2020-06-21T09:43:41Z
dc.date.available2020-06-21T09:43:41Z
dc.date.issued2018
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Keskin, C.; Inan, U.] Ondokuz Mays Univ, Dept Endodont, Fac Dent, Istanbul, Turkey; [Demiral, M.] Cekmekoy Oral & Dent Hlth Ctr, Istanbul, Turkeyen_US
dc.descriptionKeskin, Cangül/0000-0001-8990-4847en_US
dc.description.abstractAimTo compare the cyclic fatigue resistances of WaveOne Gold (Denstply Sirona, Ballaigues, Switzerland), WaveOne (Dentsply Sirona) and Reciproc (VDW, Munich, Germany) in interrupted reciprocation. MethodologyThree groups of 18 instruments each of WaveOne Gold Primary, WaveOne Primary and Reciproc R25 were subjected to cyclic fatigue tests in reciprocation and interrupted reciprocation. The instruments in group 1 were tested in reciprocation, whereas in groups 2 and 3, reciprocation was interrupted for 1s in every 5s and 10s, respectively. Cyclic fatigue resistance was tested using dynamic test devices in stainless steel, curved canals (60 degrees, r=5mm) until fracture, and the time to fracture values were recorded. The lengths of the fractured tips were also recorded, and fractured surfaces were examined with a scanning electron microscope (SEM). Data were evaluated by one-way analysis of variance and Tukey's tests. ResultsThe cyclic fatigue resistance of WaveOne Gold Primary was not affected by the interruptions (P>0.05) and exhibited significantly greater cyclic fatigue resistance than WaveOne Primary and Reciproc R25 in all groups (P<0.05). Interruptions reduced the cyclic fatigue resistance of WaveOne Primary and Reciproc R25 significantly (P<0.05). ConclusionInterrupted reciprocation reduced the cyclic fatigue resistance of Reciproc R25 andWaveOne Primary. The cyclic fatigue resistance of WaveOne Gold Primary was greater than that of WaveOne Primary and was not dependent on the occurrence of interruptions.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1111/iej.12790
dc.identifier.endpage555en_US
dc.identifier.issn0143-2885
dc.identifier.issn1365-2591
dc.identifier.issue5en_US
dc.identifier.pmid28470747
dc.identifier.scopus2-s2.0-85019737980
dc.identifier.scopusqualityQ1
dc.identifier.startpage549en_US
dc.identifier.urihttps://doi.org/10.1111/iej.12790
dc.identifier.volume51en_US
dc.identifier.wosWOS:000429544400007
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofInternational Endodontic Journalen_US
dc.relation.journalInternational Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic Fatigue Resistanceen_US
dc.subjectInterrupted Reciprocationen_US
dc.subjectReciprocen_US
dc.subjectWaveOne Golden_US
dc.titleEffect of Interrupted Motion on the Cyclic Fatigue Resistance of Reciprocating Nickel-Titanium Instrumentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files